Pioneer-PRV-LX1-Factory-Reset

Pioneer PRV-LX1 Factory Reset

Pioneer PRV-LX1 Factory Reset

The PRV-LX1 recorder ships with default settings for a typical end-user. However, your requirements may differ. The Operating Instructions provide detailed information regarding changing these defaults or reassigning settings according to your preferences. This document lists the PRV-LX1’s default settings when shipped from the factory.

To perform the Pioneer PRV-LX1 Factory Reset, follow the steps below.

1) Verify that the unit is in Standby mode.
2) Press and hold the STOP button on the recorder’s front panel.
3) Press and hold the Power button on the front panel.
4) Release both buttons simultaneously after the unit powers on.

Note: Returning the PRV-LX1 to the factory defaults does not erase or remove the imported clips or files.

DEFAULT SETTINGS PDF

 

PRV-LX1-Please-Wait

Pioneer PRV-LX1 Please Wait

Pioneer PRV-LX1 Please Wait

No Start-up “Pioneer Prv-LX1 Please Wait” on display:

Press F1 to load a new BIOS value.

Check 2.5V Battery.

If error reads (non-system disc) replace hard disc drive.

If your PRV-LX1 is flashing “PLEASE WAIT” on the LCD, or you are receiving a message CMOS checksum error, first try leaving the PRV-LX1 on for 24-hours. In some cases, this will charge the CMOS battery and resolve your problem. This fixes most CMOS battery issues on Pioneer PRV-LX1 left without power for several months. If this does not resolve your problem the battery will need to be replaced.

How to replace the CMOS Battery